Series FLA SERIES 4000 Warranty 3 Years
Volts 2 Design L16
Cells 1 Plates/Cell 53
Terminal Type LT
Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer
Size & Thread 5/16″-18
Cables Optional: 19″ 4/0 interconnect cable
Charge | Discharge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)
Float Voltage Range 2.25 V/cell @ 25°C (77°F)
Recommended Charge Current 175 A
Maximum Charge Current 290 A
Self-Discharge Rate 5%-10% per month at 25°C (77°F)
Capacity
Cold Crank Amps (CCA) 0°F / -18°C 3378
Marine Crank Amps (MCA) 32°F / 0°C 4223
Reserve Capacity (RC @ 25A) 2909 Minutes
Reserve Capacity (RC @ 75A) 764 Minutes
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
105% 100% 75% 50%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 1728 AH 17.28 A
@ 72 Hour Rate 1683 AH 23.38 A
@ 50 Hour Rate 1623 AH 32.46 A
@ 20 Hour Rate 1503 AH 75.15 A
@ 15 Hour Rate 1413 AH 94.19 A
@ 10 Hour Rate 1353 AH 135.27 A
@ 8 Hour Rate 1293 AH 161.57 A
@ 5 Hour Rate 1202 AH 240.48 A
@ 1 Hour Rate 706 AH 706.41 A
Specifications
Weight 59 kg 130 lbs
Length 318 mm 12.5
Width 181 mm 7.13
Height Incl. Term. 432 mm 17
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components.
Electrolyte Reserve 57 mm 2.25
Container High Density Polypropylene
Cover High Density Polypropylene
Handles Rope / Plastic Handle
  • Plastics are UL94 HB (UL94-V2 available)
  • Plastics are impact copolymer rated to ASTM D256, D5420
  • Vented design with integral flame arrestor vent caps

Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Detailed Illustration

 

WAREHOUSE PICKUP

BRITISH COLUMBIA

PROVINCE CITY PICKUP TIME AVAILABILITY
BC Delta Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
BC Victoria Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

ALBERTA

PROVINCE CITY PICKUP TIME AVAILABILITY
AB Calgary Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
AB Edmonton NW Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

ONTARIO

PROVINCE CITY PICKUP TIME AVAILABILITY
ON Barrie Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

NOVA SCOTIA

PROVINCE CITY PICKUP TIME AVAILABILITY
NS Halifax Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

DOWNLOADS

S2 L16-SC Data Sheet

Reviews

There are no reviews yet.

Be the first to review “Rolls S2 L16-SC 2V 1445AH Flooded Deep Cycle Battery – 2Volts”

Your email address will not be published. Required fields are marked *