Cart0items

Description

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS    
Nominal Voltage 25.6V Dimensions (L x W x H) 7.7 x 5.2 x 6.7” 195 x 131 x 171 mm
Nominal Capacity 20 Ah Weight 11.9 lbs (5.4 kg)
Capacity @ 25A 48 min Terminal Type M8 x 1.25
Energy 512Wh Terminal Torque 80 – 100 in-lbs (9 – 11 N-m)
Resistance 50 mΩ @ 50% SOC Case Material ABS
Efficiency 99% Enclosure Protection IP66
Self Discharge <3% per Month Cell Type – Chemistry Cylindrical – LiFePO4
Maximum Modules in Series 1 (Single Use    

 

DISCHARGE SPECIFICATIONS CHARGE SPECIFICATIONS
Maximum Continuous Discharge Current 30 A Recommended Charge Current 1 A – 10 A
Peak Discharge Current 60 A (7.5 s ±2.5 s) Maximum Charge Current 30 A
BMS Discharge Current Cut-Off 170 A ±20 A (10 ±5 ms) Charge Current 32ºF to 14ºF (0 to -10 ºC) ≤0.1 C
Recommended Low Voltage Disconnect 22V Charge Current -4ºF to 14ºF (-20 to -10 ºC) ≤0.05 C
BMS Discharge Voltage Cut-Off 16V (2.0 ±0.08 vpc) (20 ±6 ms) Recommended Charge Voltage 28.4 V – 29.2 V
Reconnect Voltage 20V (2.5 ±0.05 vpc) BMS Charge Voltage Cut-Off 31.2 V (3.9 ±0.025 vpc) (1 ±0.3 s)
Short Circuit Protection 200-600 μs Reconnect Voltage 30.4 V (3.8 ±0.05 vpc)
    Balancing Voltage 28.8 V (3.6 ±0.025 vpc)

 

TEMPERATURE SPECIFICATIONS COMPLIANCE SPECIFICATIONS
Discharge Temperature -4 to 140 ºF (-20 to 60ºC) Certifications CE (battery) UL1642 & IEC62133 (battery)
Charge Temperature* -4 to 113 ºF (-20 to 45ºC) Shipping Classification UN 3480, CLASS 9
Storage Temperature 23 to 95 ºF (-5 to 35ºC)    
BMS High Temperature Cut-off 176 ºF (80 ºC)    
Reconnect Temperature 122 ºF (50 ºC)    
*Refer to charge currents below 0°C (32°F)