Cart0items

Description

MECHANICAL SPECIFICATIONS
Industry Reference
Length A (in/mm) 2.8 70
Width B (in/mm) 1.9 47
Height C (in/mm) 4 101
Total Height D (in/mm) 4.2 107
Weight (lbs/kgs) 1.72 0.78
Terminal * F1
Technology AGM, VRLA

NOTE 1: Dimensions have a ±2 mm (0.08 in) tolerance. Weights may vary.
NOTE 2: Refer to terminal guide on website for torque values.

ELECTRICAL SPECIFICATIONS
Voltage (V) 6
Internal Resistance (mΩ) 20
Short Circuit (A) (20°C / 68°F) 300
Self-Discharge (20°C / 68°F) 2-3% per month
Charge Temperature Min: -10°C (14°F) | Max: 50°C (122°F)
Discharge Temperature Min: -40°C (-40°F) | Max: 50°C (122°F)
Storage Temperature -20°C (-4°F) to 60°C (140°F)

NOTE 3: Extra considerations must be given when designing systems for use at maximum temperatures.
NOTE 4: Internal Resistance is approximate.

PERFORMANCE SPECIFICATIONS
Amp Hours (AH)
1 HR 5 HR 10 HR 20 HR
3.2 4.3 4.7 5

1HR @1.60VPC, 5HR @1.75VPC; 10 HR@ 1.80VPC; 20 HR @1.80VPC. All at 30°C/86°F

Discharge Constant Current (Amperes) @ 25°C / 77°F
VPC/Time 5 MIN 10 MIN 15 MIN 30 MIN 1 HR 3 HR 5 HR 10 HR 20 HR
1.60 VPC 16.80 13.50 10.00 5.22 3.20 1.43 0.91 0.52 0.28
1.65 VPC 15.90 12.90 9.55 5.01 3.08 1.40 0.90 0.51 0.27
1.70 VPC 15.00 12.20 9.10 4.79 2.96 1.35 0.88 0.50 0.26
1.75 VPC 14.00 11.50 8.60 4.56 2.83 1.30 0.86 0.49 0.26
1.80 VPC 13.00 10.80 8.10 4.31 2.70 1.24 0.82 0.47 0.25

 

Discharge Constant Power (Watts) @ 25°C / 77°F
VPC/Time 5 MIN 10 MIN 15 MIN 30 MIN 1 HR 3 HR 5 HR 10 HR 20 HR
1.60 VPC 33.30 23.20 18.20 10.40 6.40 2.63 1.77
1.65 VPC 31.30 21.90 17.20 9.90 6.13 2.57 1.73
1.70 VPC 29.20 20.50 16.20 9.36 5.85 2.50 1.70
1.75 VPC 27.20 19.20 15.20 8.82 5.56 2.42 1.66
1.80 VPC 25.20 17.80 14.20 8.27 3.15 1.62 1.44
BENEFITS

EXTENDED SERVICE LIFE

  • Up to 5 year design life
  • Low self-discharge rates prolongs shelf life
  • 99% gas recombination extends life

EXTREME TEMPERATURES

  • Wide ambient operating temperature
  • Low temperature operation superior to FLA / Gel batteries

RELIABLE AND SAFE

  • Valve Regulated Lead-Acid, AGM
  • Maintenance-free, nonspillable, no-gassing
  • Flame retardant (UL94:V0) ABS case and cover available

CERTIFIED QUALITY

Discover® manufacturing facilities are fully certified to ISO 9001/14001 and OSHA 18001 standards.

Designed in accordance with and published in compliance with applicable standards, including:

  • IEC 60896-21/22
  • BS EN 60254-1:2005
  • UL, CE Health Safety Certified
SHIPPING CLASSIFICATION
  • Classified as a nonspillable battery
  • Without restriction for transport by Sea (IMDG amendment 27)
  • Without restriction for transport by Air (IATA/ICAO provision 67)
  • Without restriction for transport by Ground (STB, DOT-CFR-HMR49)
Temperature Effects on Float Life

gra vrla float standby temperature effects on float life

Temperature Effects on Capacity

gra vrla float standby temperature effects on capacity

Charge Characteristics (Cyclic)

gra vrla float standby charge characteristics

Discharge Characteristics

gra vrla float standby discharge characteristics

Self-Discharge Characteristics

gra vrla float standby self discharge characteristics

  1. Due to self-discharge characteristics of lead acid battery technologies, batteries should be charged within 6 months of storage to ensure optimum performance, prevent sulphation and permanent capacity loss.
  2. Charge profile recommendations correspond to battery voltages at 25°C (77°F). For temperatures below, adjust +5mVPC/°C (+3mVPC/°F). Temperatures above, adjust -5mVPC/°C (-3mVPC/°F). Temperature compensated charging helps ensure optimum battery runtime and life performance.
  3. Charge until battery voltage reaches 2.45VPC and hold until current tapers down to 0.01C20 amps. Battery is fully charged under these conditions and charger should be disconnected or switched to “float” voltage. For standby / float use, a constant charge voltage of 2.25-2.30VPC is also acceptable. Hold until the battery seeks its own current level and maintain itself in a fully charged condition.

WAREHOUSE PICKUP

BRITISH COLUMBIA

PROVINCE CITY PICKUP TIME AVAILABILITY
BC Delta Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
BC Kelowna Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
BC Prince George Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
BC Kamloops Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

ALBERTA

PROVINCE CITY PICKUP TIME AVAILABILITY
AB Calgary Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
AB Red Deer Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
AB Edmonton NW Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
AB Lethbridge Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
AB Medicine Hat Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

SASKATCHEWAN

PROVINCE CITY PICKUP TIME AVAILABILITY
SK Saskatoon Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
SK Regina Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

MANITOBA

PROVINCE CITY PICKUP TIME AVAILABILITY
MB Winnipeg Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

ONTARIO

PROVINCE CITY PICKUP TIME AVAILABILITY
ON Toronto GTA Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

QUEBEC

PROVINCE CITY PICKUP TIME AVAILABILITY
QC Saint-Eustache, Montreal Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability
QC Québec City Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

NEW BRUNSWICK

PROVINCE CITY PICKUP TIME AVAILABILITY
NB Moncton Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

NOVA SCOTIA

PROVINCE CITY PICKUP TIME AVAILABILITY
NS Halifax Warehouse Monday to Friday, 9:00 AM – 4:30 PM Confirm Availability

Reviews

There are no reviews yet.

Be the first to review “Discover D650 6V 5Ah VRLA AGM Float Standby SLA Battery F1 Terminal”

Your email address will not be published. Required fields are marked *