Description

Specification
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 40.0 Ah @ 20 hr-rate to 1.75V per cell @ 25°C (77°F)
Weight Approx. 12.92 kg (28.48 lbs)
Maximum Discharge current 400A (5sec)
Internal Resistance Approx. 8.5 mΩ
Operating Temperature Range Discharge: -15 ℃ ~50 ℃ (5 °F ~122°F )
Charge: -15 ℃ ~40 ℃ (5 °F ~104 °F )
Storge: -15 ℃ ~40 ℃ (5 °F ~104 °F )
Nominal Operating Temperature Range 25 ℃± 3 ℃ (77 °F± 5 °F )
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25 ℃ (77 °F)
Recommended Maximum Charging current limit 12A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25 ℃ (77 °F)
Self Discharge It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temp. 25℃
Terminal L terminal:B8 (M5 bolt) or Recessed type (M6 bolt)
Container Material ABS(UL94-HB) & Flammability resistance of(UL94-V0) can be available upon request.

DATASHEET

    

Reviews

There are no reviews yet.

Be the first to review “CSB GPL12400 12V 40Ah Sealed Lead Acid Battery with B2 or I2/M6 Terminal”

Your email address will not be published. Required fields are marked *